格力空調細管涼,粗管不涼是什么原因

作者:格力空調維修  發表時間:2018/5/4  點擊數:1904次

  格力空調細管涼,粗管不涼是什么原因


      KONGDIAOXIGUANLIANG,CUGUANBULIANG,ZHEMINGXIANSHIQUEZHILENGJIDEXIANXIANG。


  首先保證室內外機清洗干凈,通風順暢,也是保證空調正常工作最基本的條件,包括室內過濾網、室外機翅片干凈。根據使用情況,建議每年至少清洗2次。

  其次空調制冷不好或不制冷不見得就是缺制冷劑,在空調質量沒問題安裝到位的情況下,空調用到超過設計壽命都不會缺制冷劑的。

  作為一個非專業人員如何簡單的判斷空調是否缺制冷劑那,觀察和摸一下室外機高低壓閥霜露情況和溫度吧。

  1、正常的情況下高壓閥干燥且有一定的余溫(長時間工作在制冷狀態也會有有少量的冷凝水),低壓閥濕潤且有水露,水露多少根據天氣情況而定。


  2、高壓閥干燥(長時間工作在制冷狀態也會有有少量的冷凝水),低壓閥結霜,那是缺制冷劑。

  3、高壓閥結霜,低壓閥也結霜或干燥,那是嚴重缺制冷劑或系統微堵。

  4、GAOYAFAGANZAOBULIANG,DIYAFAGANZAOBULIANG,SHIXITONGYANZHONGXIELOUHUOZHEYASUOJIMEIYOUGONGZUO。


YINGWENFANYI


What is the reason why the GREE air conditioner is cool and the rough pipe is not cool

The air conditioning tube is cool, and the rough pipe is not cool. This is obviously the phenomenon of lacking refrigerant.

In the first place, the indoor and outdoor machines are cleaned and the ventilation is smooth. It is also the basic condition to ensure the normal work of the air conditioning, including the indoor filter net and the outdoor fin clean. According to the usage situation, it is recommended to clean at least 2 times a year.

Secondly, the air conditioning refrigeration is not good or refrigerant is not the refrigerant, in the condition that the quality of air conditioning is not installed in place, the air conditioner will not lack the refrigerant for more than the design life.

As a non professional person, how to make a simple judgement whether air conditioning is short of refrigerant, observe and touch the outdoor high and low pressure valve dew and temperature.
It
1, under normal conditions, the high pressure valve is dry and there is a certain Yu Wen (long time working in the cooling state also has a small amount of condensate), low pressure valve humid and water dew, the amount of water according to the weather conditions.

2, high pressure valve drying (long time work in the refrigeration state will also have a small amount of condensate), low pressure valve frosting, that is the lack of refrigerant.

3, high pressure valve frosting, low pressure valve frosting or drying, which is seriously lack of refrigerant or system micro blockage.

4, high pressure valve drying is not cool, low pressure valve drying is not cool, is a serious leakage of the system or compressor does not work.